Tankalert Eco Oil Plus

It allows to remote monitoring the volume at underground tanks, or with FM communication difficulties with the receiver.
TANK Min. 0,5 m (depth) - Max 3 m (depth or wide) Max 19.999 litres - Min 300 litres (content)
MEASUREMENT DISPLAY Multi-function LCD display including: -- 10 bar-graph level indication on both Inpro EcoOil Monitor and Transmitter* --Display of various current and historical values --Display control with five control buttons. --Red LED for low level indication at 5% or less of usable fuel remaining. -- Audible alarm sounds every hour on the hour when the tank level is low. * The transmitter and Monitor bar-graph displays may differ (see display symbol reference table).
MAX COMUNICATION DISTANCE Typically 150m in normal ‘line of sight’ conditions
POWER SUPPLY Receiver: --Mains Power Supply (included): 150V-240V, 50-60 Hz, meets EN60950-1. (5V DC (40mA)) --Back up battery**: 3V LiMn ** This device contains a small battery to keep time during power cuts. If the device is left unpowered for an extended period then the battery will deplete.
BATTERY LIFE Transmitter: 5 years (estimated life)
WIRELESS COM 433MHz FM transmission (EN300-220)
DIMENSIONS Receiver: 120mm x 90mm x 50mm Transmitter: 140m x 70mm x 40mm
MAX AND MIN OPERATION (TRANSMITTER) Operating temperature range: -10°C to +60°C Operating Humidity : 0 -95% non-condensing
HOLE SIZE FOR TANK FITTING 60 mm or 2”, 1½”, 1¼”, thread
Warranty 2 years